Nuestros sensores de nivel continuo proporcionan datos en tiempo real para una mayor precisión y control. Haga más con una señal continua, tales como 4-20mA, salida de voltaje o Modbus. El registro de datos y control remoto son sólo dos de las posibilidades con la medición continua de nivel.

DC Powered Ultrasonic Sensors


IRU-2420 Ultrasonic Level Sensor

 

Range: 1 to 25 ft.
Mount: 2 in. NPT
Output: 4-20mA, 2 Trip Points
Certification: CE, CSA Class 1, Div. 2

IRU-2000 Ultrasonic Sensor

 

Range: 1 to 25 ft.
Mount: Surface (4 Screws)
Output: 4-20mA, RS-485, 2 Trip Points, Solid State Relay
Certification: CSA General Purpose

IRU-3430 Ultrasonic Level Sensor

 

Range: 1.5 to 50 ft.
Mount: 3 in. NPT
Output: 4-20mA, 2 Trip Points
Certification: CE, CSA Class 1, Div. 2

IRU-9400 Ultrasonic Sensor

Greater Sensitivity for Indoor Use

Range: 0.5 to 35 ft.
Mount: 2 in. NPT
Output: 4-20mA, 2 Trip Points
Certification: CE, CSA General Purpose

IRU-5000 Ultrasonic Level Sensors

 

Range: 4 to 79 in.
Mount: 1 or 2 in. NPT
Output: 4-20mA, 2 Trip Points, 0-2.5 V, 0-5 V
Certification: CE, CSA Class 1, Div. 2

 
IRU-6429 Ultrasonic Level Sensor

Excitation for Data Logging

Range: 1 to 30 ft.
Mount: 2 in. NPT
Output: 0-2.5 V, 0-5 V
Certification: CE, CSA General Purpose

 

Loop Powered Ultrasonic Sensors


LPU-2428 Loop-Powered Ultrasonic Sensor

Open Channel Flow Monitoring with Totalization

Range: 1 to 25 ft.
Mount: 2 in. NPT
Output: 4-20mA
Certification: CSA Class 1, Div. 1

 
LPU-2127 Loop-Powered Ultrasonic Sensor

Built-in Display and Keypad

Range: 1 to 25 ft.
Mount: 2 in. NPT
Output: 4-20mA
Certification: CSA Class 1, Div. 2

 

Remote Monitoring Ultrasonic Sensors


LOE Remote Monitoring Ultrasonic Sensor

Tank Cloud Master Ultrasonic Sensor

Range: 4 in. to 40 ft.
Mount: 2 or 3 in. NPT
Connectivity: LAN or Internet
Certification: CSA Class 1, Div. 2

 
MNU Remote Monitoring Ultrasonic Sensor

Tank Cloud Slave Ultrasonic Sensor

Range: 4 in. to 40 ft.
Mount: 1, 2 or 3 in. NPT
Output: Modbus RTU (RS-485)
Accuracy:±0.25% Detected Range

 

Ultrasonic Sensor/Controller Systems


DST Ultrasonic Level Sensors

For Use with DCR Controllers

Range: 4 in. to 50 ft.
Mount: 2 or 3 in. NPT
Output: 0-2.5 V, 0-5 V
Certification: CSA General Purpose

 
DCR Controllers

For Use with DST Ultrasonic Sensors

Input: DST Senors, 4-20mA, 4 Dry Contacts
Output: 4 NO Relays, 4-20mA, 0-5 V, 0-10 V
Protection: NEMA 4X, IP65, NEMA 1, IP10

 

Magnetostrictive Level Probes


MPX Magnetostrictive Liquid Level Sensor

High Accuracy Tank Cloud Level Sensor

Max Length: 25 ft.
Mount: NPT, Flange, No Mount
Output: 4-20mA Loop-Powered, Modbus RTU (RS-485)
Certification: CSA Explosion Proof Class 1, Div. 1

Resistive Chain Level Probes


RPM Liquid Level Probe

Large Hazardous Location Level Probe

Max Length: Custom
Mount: NPT, No Mount, Flange
Output: 4-20mA Loop-Powered, Resistive
Certification: CSA Explosion Proof Class 1, Div. 1

 
RP Liquid Level Probe

Level Probe for Small Tanks

Max Length: 96 in.
Mount: 2 in. NPT
Output: 4-20mA, Resistive
Certification: CSA Class 1, Div. 1

 

Submersible Pressure Transducers


PT-500 Submersible Pressure Transducers

Hydrostatic Pressure Sensor

Output: 4-20mA
Range: Up to 450 ft.
Lightening Protection: IEC 61000-4-5
Certification: CSA Class 1, Div. 1

 

Remote Communications Modules


RST-5000 Internet Communications Modules

Tank Cloud Master Module, Remote Monitoring for any 4-20mA Device

Input: RS-485, 4-20mA
Connectivity: LAN or Internet
Mount: Din Rail

 

Remote Monitoring System


MND Tank Cloud Modbus Display

Modbus Network Display, Tank Cloud Master Module

Input: RS-485
Mount: Panel, Handheld
Modes: Master, Sniffer